Compare commits
3
Commits
278d30c421
...
a3963ff91b
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
a3963ff91b | ||
|
|
518b422915 | ||
|
|
98f5705224 |
+35
-22
@@ -4,6 +4,7 @@
|
|||||||
import socket
|
import socket
|
||||||
import binascii
|
import binascii
|
||||||
import logging
|
import logging
|
||||||
|
import time
|
||||||
|
|
||||||
class APSystemsInvalidData(Exception):
|
class APSystemsInvalidData(Exception):
|
||||||
pass
|
pass
|
||||||
@@ -58,13 +59,40 @@ class APSystemsECUR:
|
|||||||
self.reader = None
|
self.reader = None
|
||||||
self.writer = None
|
self.writer = None
|
||||||
|
|
||||||
def query_ecu(self):
|
def _query(self, command, description):
|
||||||
sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
deadline = time.monotonic() + self.timeout
|
||||||
sock.connect((self.ipaddr,self.port))
|
with socket.create_connection(
|
||||||
|
(self.ipaddr, self.port), timeout=self.timeout) as sock:
|
||||||
|
remaining = deadline - time.monotonic()
|
||||||
|
if remaining <= 0:
|
||||||
|
raise socket.timeout(f'{description} timed out connecting to ECU')
|
||||||
|
sock.settimeout(remaining)
|
||||||
|
sock.sendall(command.encode('utf-8'))
|
||||||
|
|
||||||
|
response = bytearray()
|
||||||
|
while True:
|
||||||
|
terminator = response.find(self.recv_suffix)
|
||||||
|
if terminator >= 0:
|
||||||
|
end = terminator + len(self.recv_suffix)
|
||||||
|
return bytes(response[:end])
|
||||||
|
|
||||||
|
remaining = deadline - time.monotonic()
|
||||||
|
if remaining <= 0:
|
||||||
|
raise socket.timeout(f'{description} timed out waiting for ECU response')
|
||||||
|
sock.settimeout(remaining)
|
||||||
|
chunk = sock.recv(self.recv_size)
|
||||||
|
if not chunk:
|
||||||
|
raise APSystemsInvalidData(
|
||||||
|
f'{description} connection closed before response terminator')
|
||||||
|
|
||||||
|
response.extend(chunk)
|
||||||
|
if len(response) > self.recv_size:
|
||||||
|
raise APSystemsInvalidData(
|
||||||
|
f'{description} response exceeded {self.recv_size} bytes')
|
||||||
|
|
||||||
|
def query_ecu(self):
|
||||||
logging.debug('ecu query: %s', self.ecu_query)
|
logging.debug('ecu query: %s', self.ecu_query)
|
||||||
sock.sendall(self.ecu_query.encode('utf-8'))
|
self.ecu_raw_data = self._query(self.ecu_query, 'ECU query')
|
||||||
self.ecu_raw_data = sock.recv(self.recv_size)
|
|
||||||
|
|
||||||
logging.debug('raw ecu data: %s', self.ecu_raw_data)
|
logging.debug('raw ecu data: %s', self.ecu_raw_data)
|
||||||
logging.debug('ecu id: %s', self.ecu_raw_data[13:25])
|
logging.debug('ecu id: %s', self.ecu_raw_data[13:25])
|
||||||
@@ -73,33 +101,18 @@ class APSystemsECUR:
|
|||||||
|
|
||||||
self.process_ecu_data()
|
self.process_ecu_data()
|
||||||
|
|
||||||
sock.shutdown(socket.SHUT_RDWR)
|
|
||||||
sock.close()
|
|
||||||
sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
|
||||||
sock.connect((self.ipaddr,self.port))
|
|
||||||
|
|
||||||
cmd = self.inverter_query_prefix + self.ecu_id + self.inverter_query_suffix
|
cmd = self.inverter_query_prefix + self.ecu_id + self.inverter_query_suffix
|
||||||
logging.debug('inverter data cmd: %s', cmd)
|
logging.debug('inverter data cmd: %s', cmd)
|
||||||
sock.sendall(cmd.encode('utf-8'))
|
self.inverter_raw_data = self._query(cmd, 'Inverter query')
|
||||||
self.inverter_raw_data = sock.recv(self.recv_size)
|
|
||||||
|
|
||||||
logging.debug('raw inverter data: %s', self.inverter_raw_data)
|
logging.debug('raw inverter data: %s', self.inverter_raw_data)
|
||||||
|
|
||||||
sock.shutdown(socket.SHUT_RDWR)
|
|
||||||
sock.close()
|
|
||||||
sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
|
||||||
sock.connect((self.ipaddr,self.port))
|
|
||||||
|
|
||||||
cmd = self.inverter_signal_prefix + self.ecu_id + self.inverter_signal_suffix
|
cmd = self.inverter_signal_prefix + self.ecu_id + self.inverter_signal_suffix
|
||||||
logging.debug('inverter signal cmd: %s', cmd)
|
logging.debug('inverter signal cmd: %s', cmd)
|
||||||
sock.sendall(cmd.encode('utf-8'))
|
self.inverter_raw_signal = self._query(cmd, 'Inverter signal query')
|
||||||
self.inverter_raw_signal = sock.recv(self.recv_size)
|
|
||||||
|
|
||||||
logging.debug('raw signal data: %s', self.inverter_raw_signal)
|
logging.debug('raw signal data: %s', self.inverter_raw_signal)
|
||||||
|
|
||||||
sock.shutdown(socket.SHUT_RDWR)
|
|
||||||
sock.close()
|
|
||||||
|
|
||||||
data = self.process_inverter_data()
|
data = self.process_inverter_data()
|
||||||
|
|
||||||
data['ecu_id'] = self.ecu_id
|
data['ecu_id'] = self.ecu_id
|
||||||
|
|||||||
+40
-2
@@ -21,6 +21,35 @@ solar_data = {}
|
|||||||
|
|
||||||
from influxdb import InfluxDBClient
|
from influxdb import InfluxDBClient
|
||||||
client = InfluxDBClient('localhost', 8086, database='solar2')
|
client = InfluxDBClient('localhost', 8086, database='solar2')
|
||||||
|
influx_probe = InfluxDBClient('localhost', 8086, timeout=2)
|
||||||
|
INFLUX_STARTUP_TIMEOUT = 60
|
||||||
|
INFLUX_RETRY_INTERVAL = 2
|
||||||
|
|
||||||
|
async def wait_for_influxdb():
|
||||||
|
loop = asyncio.get_running_loop()
|
||||||
|
deadline = loop.time() + INFLUX_STARTUP_TIMEOUT
|
||||||
|
last_error = None
|
||||||
|
|
||||||
|
while True:
|
||||||
|
remaining = deadline - loop.time()
|
||||||
|
if remaining <= 0:
|
||||||
|
logging.warning(
|
||||||
|
'InfluxDB did not become ready within %s seconds; starting anyway (last error: %s)',
|
||||||
|
INFLUX_STARTUP_TIMEOUT, last_error)
|
||||||
|
return
|
||||||
|
|
||||||
|
try:
|
||||||
|
await asyncio.wait_for(
|
||||||
|
asyncio.to_thread(influx_probe.ping), timeout=min(2, remaining))
|
||||||
|
logging.info('InfluxDB is ready')
|
||||||
|
return
|
||||||
|
except Exception as err:
|
||||||
|
last_error = err
|
||||||
|
remaining = deadline - loop.time()
|
||||||
|
if remaining <= 0:
|
||||||
|
continue
|
||||||
|
logging.debug('InfluxDB is not ready yet: %s', err)
|
||||||
|
await asyncio.sleep(min(INFLUX_RETRY_INTERVAL, remaining))
|
||||||
|
|
||||||
async def proxy(reader, writer):
|
async def proxy(reader, writer):
|
||||||
message = await reader.read(1024)
|
message = await reader.read(1024)
|
||||||
@@ -51,6 +80,7 @@ async def get_data():
|
|||||||
global solar_data
|
global solar_data
|
||||||
|
|
||||||
await asyncio.sleep(1)
|
await asyncio.sleep(1)
|
||||||
|
await wait_for_influxdb()
|
||||||
|
|
||||||
while True:
|
while True:
|
||||||
try:
|
try:
|
||||||
@@ -122,7 +152,10 @@ async def get_data():
|
|||||||
client.write_points(points)
|
client.write_points(points)
|
||||||
|
|
||||||
logging.info('Wrote %s points to InfluxDB', len(points))
|
logging.info('Wrote %s points to InfluxDB', len(points))
|
||||||
|
else:
|
||||||
|
logging.info(
|
||||||
|
'ECU poll completed; no new sample (ECU time: %s)',
|
||||||
|
data['timestamp'])
|
||||||
|
|
||||||
prev_ecu_timestamp = data['timestamp']
|
prev_ecu_timestamp = data['timestamp']
|
||||||
|
|
||||||
@@ -154,7 +187,12 @@ async def history(request):
|
|||||||
end = int(end.timestamp())
|
end = int(end.timestamp())
|
||||||
|
|
||||||
q = 'select * from ecu where time >= {}s and time < {}s'.format(start, end)
|
q = 'select * from ecu where time >= {}s and time < {}s'.format(start, end)
|
||||||
history = list(client.query(q).get_points())
|
try:
|
||||||
|
await asyncio.wait_for(asyncio.to_thread(influx_probe.ping), timeout=2)
|
||||||
|
history = list(client.query(q).get_points())
|
||||||
|
except Exception as err:
|
||||||
|
logging.warning('InfluxDB unavailable for history request: %s', err)
|
||||||
|
raise web.HTTPServiceUnavailable(text='InfluxDB is not ready') from err
|
||||||
|
|
||||||
return web.json_response(history)
|
return web.json_response(history)
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue