Example using the SparkFun HX711 breakout board with a scale
|
||
|
By: Nathan Seidle
|
||
|
SparkFun Electronics
|
||
|
Date: November 19th, 2014
|
||
|
License: This code is public domain but you buy me a beer if you use this and we meet someday (Beerware license).
|
||
|
|
||
|
This is the calibration sketch. Use it to determine the calibration_factor that the main example uses. It also
|
||
|
outputs the zero_factor useful for projects that have a permanent mass on the scale in between power cycles.
|
||
|
|
||
|
Setup your scale and start the sketch WITHOUT a weight on the scale
|
||
|
Once readings are displayed place the weight on the scale
|
||
|
Press +/- or a/z to adjust the calibration_factor until the output readings match the known weight
|
||
|
Use this calibration_factor on the example sketch
|
||
|
|
||
|
This example assumes pounds (lbs). If you prefer kilograms, change the Serial.print(" lbs"); line to kg. The
|
||
|
calibration factor will be significantly different but it will be linearly related to lbs (1 lbs = 0.453592 kg).
|
||
|
|
||
|
Your calibration factor may be very positive or very negative. It all depends on the setup of your scale system
|
||
|
and the direction the sensors deflect from zero state
|
||
|
This example code uses bogde's excellent library: https://github.com/bogde/HX711
|
||
|
bogde's library is released under a GNU GENERAL PUBLIC LICENSE
|
||
|
Arduino pin 2 -> HX711 CLK
|
||
|
3 -> DOUT
|
||
|
5V -> VCC
|
||
|
GND -> GND
|
||
|
|
||
|
Most any pin on the Arduino Uno will be compatible with DOUT/CLK.
|
||
|
|
||
|
The HX711 board can be powered from 2.7V to 5V so the Arduino 5V power should be fine.
|
||
|
|
||
|
*/
|
||
|
|
||
|
#include "HX711.h"
|
||
|
|
||
|
#define DOUT 30
|
||
|
#define CLK 27
|
||
|
|
||
|
HX711 scale;
|
||
|
|
||
|
float calibration_factor = -7050; //-7050 worked for my 440lb max scale setup
|
||
|
|
||
|
void setup() {
|
||
|
Serial.begin(115200);
|
||
|
Serial.println("HX711 calibration sketch");
|
||
|
Serial.println("Remove all weight from scale");
|
||
|
Serial.println("After readings begin, place known weight on scale");
|
||
|
Serial.println("Press + or a to increase calibration factor");
|
||
|
Serial.println("Press - or z to decrease calibration factor");
|
||
|
|
||
|
scale.begin(DOUT, CLK);
|
||
|
digitalWrite(CLK, LOW); // hangs without this
|
||
|
scale.set_scale();
|
||
|
scale.tare(); //Reset the scale to 0
|
||
|
|
||
|
long zero_factor = scale.read_average(); //Get a baseline reading
|
||
|
Serial.print("Zero factor: "); //This can be used to remove the need to tare the scale. Useful in permanent scale projects.
|
||
|
Serial.println(zero_factor);
|
||
|
}
|
||
|
|
||
|
void loop() {
|
||
|
|
||
|
scale.set_scale(calibration_factor); //Adjust to this calibration factor
|
||
|
|
||
|
Serial.print("Reading: ");
|
||
|
Serial.print(scale.get_units(), 1);
|
||
|
Serial.print(" lbs"); //Change this to kg and re-adjust the calibration factor if you follow SI units like a sane person
|
||
|
Serial.print(" calibration_factor: ");
|
||
|
Serial.print(calibration_factor);
|
||
|
Serial.println();
|
||
|
|
||
|
if(Serial.available())
|
||
|
{
|
||
|
char temp = Serial.read();
|
||
|
if(temp == '+' || temp == 'a')
|
||
|
calibration_factor += 10;
|
||
|
else if(temp == '-' || temp == 'z')
|
||
|
calibration_factor -= 10;
|
||
|
}
|
||
|
}
|